Both Sides Warm, or Silent

Not cooling at all, before anyone says compressor.

When a built-in refrigerator is warm on both sides, or silent, the makers’ troubleshooting starts with the power, the settings and the parts both sides share. The compressor comes late, or not at all. A Sub-Zero’s two systems share one control board, one dual condenser and its fan, and its service manual, for both sides warm, names no compressor fault.

On This Page

  1. What each maker checks first
  2. Is it even on?
  3. What a Sub-Zero’s two systems share
  4. How GE checks a Monogram
  5. Broken, or only waiting
  6. When cleaning is not enough
  7. What to do right now
  8. When it is a visit
  9. Questions
  10. Sources

What Each Maker Checks First

Three built-ins, three starting points, each row with the pages it comes from.

Is it on?Before calling it deadThe maker’s first checksSource
Sub-Zero Built-In 600-2A faint OFF: switched off at the panel. Two dashes: a compartment disabled on purpose. Lights on and no cold: Showroom ModeAt least three minutes after being switched off and onBoth sides warm: power, OFF, Showroom Mode, the set-point, a warm load, a room above 90°F, a door ajar, condenser airflow, one thermistor. No compressor, no sealed systemService manual, pp. 3-6, 3-14, 3-17 to 3-19, 8-13 and 8-14
Viking VCRB5301 / VCRB5361A power switch behind the top grille. Two dashes for about thirty seconds when power is first applied are normalAt least six minutes between compressor runsWill not operate: the power supply, the circuit breaker, the power switchService manual SMR-0022, pp. 6, 11 and 39
GE Monogram ZIS side-by-sideThe interior lights first; if they are dark, the house supply, then the power cord and its connectorA defrost: up to 35 minutes of heater and a 20-minute dwell, compressor and fans offBoth sides warm: settings, gasket, door switch, condenser fan, evaporator fan, then the compressor; airflow, thermistors, and the sealed system lastService guide 31-9091, pp. 20, 55 and 58

Series differ, and the rating tag inside the cabinet says which row is yours: find your model number.

Is It Even On?

Four things look like a failure and are something else.

  1. 01

    A faint OFF, or two dashes

    On a Sub-Zero Built-In 600-2, a faint OFF means the unit has power and was switched off at its own panel; the ON/OFF key turns it back on. Two dashes where a temperature belongs mean that compartment was disabled on purpose while the other keeps cooling. On a Viking VCRB, two dashes are normal for about thirty seconds after power is first applied.

  2. 02

    Lights on, and no cold at all

    Sub-Zero’s Showroom Mode disables all cooling and leaves the lights on, and Sub-Zero calls it likely only on a former display unit. GE’s answer to lights without cooling is to check that the controls were not turned off by accident, and its list includes a demo mode.

  3. 03

    Dark, and still cold

    Sabbath Mode on a Sub-Zero 600-2 darkens the display and the lights while the compressors keep cycling, and Viking’s manual answers “running and no lights” with Sabbath Mode. A Monogram ZIS gives its lights a master switch behind the grille and two breakers of their own, so dark lights there can mean a light circuit rather than a dead refrigerator.

  4. 04

    No power at all

    Sub-Zero’s list for a unit that will not turn on: switch the home breaker to it off for ten seconds and back on, check the cord, test the outlet with another appliance, and make sure the unit is not on a GFCI, an outlet or breaker that trips on its own. A Viking VCRB has a power switch behind its top grille, turned off for cleaning; Viking lists it with the supply and the breaker.

First, write down what the display shows. A power cycle clears a Sub-Zero’s flashing SERVICE, and GE asks that a unit awaiting service stay plugged in so its symptoms do not disappear.

What do a Sub-Zero’s two systems share?

On the two-compartment Built-In 600-2 models, each side has its own compressor, filter-drier and evaporator, and its own circuit through a dual condenser. What the two share is short: one control board, that condenser and one fan. The fan belongs to neither side; the control runs it whenever either compressor runs, and stops it only when both have stopped.

Two circuits that never meet would both have to fail at once, while one fan, one coat of dust or one board can stop both. For both compartments warm without SERVICE flashing, Sub-Zero’s guide lists no power, the unit switched OFF, Showroom Mode, a set-point too high, a warm load of food, a room above 90°F, a door ajar and condenser airflow; with SERVICE flashing, the room, condenser airflow and one thermistor. Neither list names the compressor or the sealed system.

Condenser airflow, in the manual, means a dirty condenser, a fan blade blocked or loose, a fan motor disconnected or failed, or no power from the board to the fan. A flashing 40 or 50 with EC and SERVICE records a compressor running without rest, and Sub-Zero’s guide for either code checks the door, the condenser, its fan and the board’s power to it before its last step, the sealed system. What each code means.

One side warm reads differently: one system has stopped and its twin runs on. Refrigerator warm, freezer perfect.

In what order does GE check a Monogram?

A Monogram ZIS side-by-side runs one sealed system for both compartments. Even so, GE’s flowchart for “Fresh Food Warm – Freezer Warm” works from the outside in: the settings, with 24 hours to stabilize after a change; the door gasket and door switch; the condenser fan; the evaporator fan; whether the compressor runs at all; airflow and frost; the thermistors; and only then the sealed system.

Its chart for a compressor that is not running starts at the main control board: no 120 volts from the board, and the board is replaced. If the compressor then starts when tested directly, GE sends the technician to its wiring, overload and relay. The chart for a Monogram that is dead, with no sound and no cooling, runs from the interior lights to the house supply, the cord, the two control boards, a short in a fan motor circuit and the thermistors; the compressor is not on it.

The same guide ties two parts together: a condenser fan that shorts damages the main control board, and when the board’s resistor has burnt, the fan and the board are replaced together. What we repair on a Monogram · which parts sit inside the sealed system.

Broken, or only waiting?

All three go quiet on purpose, above all after the power returns. A Viking VCRB will not restart its compressor and condenser fan until they have been off for six minutes; a flashing POWER on its display only reports that the power was lost, and ALARM OFF clears it. A Sub-Zero 600-2 holds its compressors off at least three minutes after being switched off and on, to protect them.

GE says a defrost can stop the compressor and fans for as long as 30 to 45 minutes, depending on the model. After a short outage, GE adds, it is the compressor’s overload that cycles on and off, not the compressor, until the refrigerant system equalizes.

Once it runs, give it a day: Sub-Zero allows 24 hours for temperatures to come back after anything is corrected. What we repair on a Viking · what to keep after an outage.

When is a condenser cleaning not enough?

Sub-Zero suggests cleaning the condenser, with the unit switched off at its control, if that has not been done in six months. Why desert dust makes it matter here.

It also draws a line. If the refrigerator reads above 48°F while set to 38°F, the setting Sub-Zero recommends, it says the unit is unlikely to recover from a condenser cleaning, and its next step is service.

What to Do Right Now

Six steps, in this order.

  • 01 Write down what the display shows before anything is switched off SERVICE · OFF · a code
  • 02 Keep the doors shut, and put an appliance thermometer in each compartment the 40°F line
  • 03 Check the breaker and the outlet, and on a Viking the switch behind the top grille power
  • 04 Rule out OFF, two dashes, Showroom Mode and Sabbath Mode settings, not faults
  • 05 Give it the maker’s minutes: three on a Sub-Zero, six on a Viking, a defrost on a Monogram restart delay
  • 06 Still warm after all five, or above 48°F at a 38°F setting? Call a visit

For the food, go by the thermometer rather than the smell. FoodSafety.gov draws the line at 40°F: perishable food held above it for more than two hours is thrown out, and never tasted to decide. FoodSafety.gov, “Food Safety During Power Outage” · the keep-or-discard chart.

When is it a visit?

When the list above is done and it is still warm. Sooner, when the machine says so itself: SERVICE or a code on a Sub-Zero, or on a Viking oPn or Shr, a thermistor open or shorted, or the HIGH TEMP alarm its control raises after three hours above 50°F.

The visit is $119, waived in full when you go ahead with the repair. Nobody can honestly price a symptom that runs from a breaker to a sealed system over the phone. If it is sealed-system or control work, labor on a built-in like this is typically $500–600, one fixed number approved before any repair begins, with genuine OEM parts quoted separately. What the $119 diagnostic actually buys.

Still inside the maker’s warranty? Call the maker first: a covered repair should cost you nothing. Is the built-in still under warranty? · What we repair on a Sub-Zero.

Questions

My Sub-Zero is warm on both sides. Is it the compressor?

Not by Sub-Zero’s own list. A built-in Sub-Zero has a compressor for each compartment, and for both compartments warm its service manual lists power, the OFF and Showroom settings, the set-point, a warm load, the room, a door ajar, condenser airflow and one thermistor, but not the compressor or the sealed system. What the two sides share, one control board, one dual condenser and its fan, is where to look first.

My refrigerator won’t turn on at all. What should I check first?

Write down anything on the display, then check the power. Sub-Zero’s list: the home breaker off for ten seconds and back on, the cord, the outlet tested with another appliance, and no GFCI or Sabbath Mode in the way. A Viking VCRB has a power switch behind its top grille that must be back on after cleaning. On a Monogram, GE starts with the interior lights, then the house supply and the cord.

It has gone silent. How long should I wait before calling?

Minutes for the restart, a day for the temperature. A Sub-Zero 600-2 holds its compressors off at least three minutes after being switched off and on, a Viking VCRB six minutes between runs, and GE says a defrost can stop the compressor and fans for as long as 30 to 45 minutes, depending on the model. Once it runs, Sub-Zero allows 24 hours to return to normal. Not started within a few hours, or showing an error? Note it and call.

Will cleaning the condenser fix a refrigerator that is warm on both sides?

It can, when dust is the cause: a dirty condenser is on Sub-Zero’s list for both compartments warm, and Sub-Zero suggests cleaning it if that has not been done in six months. But Sub-Zero also says a refrigerator reading above 48°F while set to 38°F is unlikely to recover from a condenser cleaning. Past that point, the next step is service.

Sources

  1. Sub-Zero Built-In (600-2) Series technical service manual (Job Aid #3758407, 2005): the OFF trace and the ON/OFF key (p. 3-6), the condenser fan run whenever either compressor runs (p. 3-10), the three-minute minimum off time and codes 40 and 50 (p. 3-14), Sabbath and Showroom Modes (p. 3-17), Manual Compartment Disable Mode (p. 3-18), the indicators an owner may see, the double dashes among them (p. 3-19), the dual condenser (p. 4-7), the guide for codes 40 and 50 (p. 8-4), the SERVICE indicator cleared by a power cycle (p. 8-8), and the entries for both compartments warm, with and without SERVICE flashing (pp. 8-13, 8-14).
  2. Sub-Zero, unit does not turn on and shuts off by itself: the ten-second breaker reset, the cord and the outlet test, the GFCI, Sabbath Mode, the On/Off button, and O FF on the display.
  3. Sub-Zero, warm refrigerator or freezer troubleshooting: 38°F as the recommended setting, the condenser cleaned if it has not been in six months, above 48°F at 38°F as unlikely to recover from a cleaning, Showroom Mode on former display units, and 24 hours to return to normal.
  4. Sub-Zero, 600, 500 and 200/300 Series condenser cleaning: the unit switched off at its control before the condenser is cleaned.
  5. Viking Preferred Service manual SMR-0022 for the built-in all-refrigerator VCRB5301 / VCRB5361, May 2012: the power switch behind the top grille and the dashes when power is first applied (p. 6), Sabbath Mode (pp. 9, 39), the six-minute compressor dwell (p. 11), the HIGH TEMP, open and shorted thermistor and power-loss alarms (pp. 33, 34), and the troubleshooting table for a unit that will not operate (p. 39).
  6. GE Consumer Home Services technical service guide 31-9091 (2002) for Monogram side-by-side refrigerators ZIS360, ZIS420 and ZIS480: the condenser fan and the main control board (p. 19), defrost heater time and dwell (p. 20), the master light switch and the light-circuit breakers (pp. 45, 46), and the flowcharts “Fresh Food Warm – Freezer Warm” (p. 55), “Compressor Not Running” (p. 57) and “Refrigerator Dead – No Sound, No Cooling” (p. 58).
  7. GE Appliances, Refrigerator – Does Not Run or Cool: the light check, controls turned off by accident, a demo mode, a defrost of 30 to 45 minutes, the overload cycling after a short outage, and keeping the refrigerator plugged in for service.
  8. FoodSafety.gov, “Food Safety During Power Outage”: the appliance thermometer, the 40°F line, two hours, and never tasting food to judge it.

Written from these sources and reviewed on by Aphelion Appliance Repair, Phoenix. The manuals cover the Sub-Zero Built-In 600-2, the Viking VCRB5301 / VCRB5361 and the Monogram ZIS side-by-side, and other series differ. Nothing here is a manufacturer’s instruction, and anything inside a sealed system is a technician’s work.